Glaucomatous damage detected with SD-OCT - Ophthalmology Times Europe

ADVERTISEMENT

CATARACT

GLAUCOMA

REFRACTIVE

RETINA

Glaucomatous damage detected with SD-OCT

Ophthalmology Times Europe

SD-OCT imaging and retinal nerve fibre layer (RNFL) assessment successfully detects pre-perimetric glaucomatous damage, according to a recent study in the journal Ophthalmology.

Dr Renato Lisboa et al., Hamilton Glaucoma Center, Department of Ophthalmology, University of California San Diego, California, USA, studied a cohort of 134 eyes of 88 glaucoma suspects on their optic disc appearance. There was also a control group consisting of 86 eyes of 46 patients without any evidence of progressive glaucomatous change. The main outcome measures included areas under the receiver operating characteristic curves (AUCs) and likelihood ratios (LRs).

All patients experienced RNFL imaging with Spectralis SD-OCT and topographic imaging with the Heidelberg Retina Tomograph III CSLO within six months of one another. At the time of imaging all patients had normal visual fields and were identified on history of documented stereophotographic evidence of progressive glaucomatous change and optic nerve appearance before imaging.

The largest AUC obtained with SD-OCT was the temporal superior RNFL thickness followed by global RNFL thickness and temporal inferior RNFL thickness. The largest AUC obtained with the CSLO was rim area followed by rim volume and linear cup-to-disc ratio.

The temporal superior RNFL average thickness measured by SD-OCT was significantly better than CSLO-obtained rim area measurements. The SD-OCT was the most effective method for detecting preperimetric glaucomatous damage in a cohort of glaucoma suspects, compared to CSLO.

The abstract can be viewed here .

On a scale of 1 to 10, with 1 being the lowest and 10 being the highest, how would you rate this article?
Your original vote has been tallied and is included in the ratings results.
View our top pages
Average rating for this page is: 7.09
WHAT DO YOU THINK?

AddThis Social Bookmark Button

Rate this article
Your comments
Discuss on our forum
Follow us on Twitter

 

Survey
Which clear corneal incision technique do you use the most?
Three-plane incision
Single-plane angled manual incision
Three-plane incision
53%
Single-plane angled manual incision
47%
Source: Ophthalmology Times Europe,
Click here