Comparative study on keratitis therapies


Ophthalmology Times Europe
Volume 7, Issue 4

Keratitis is a major cause of sight loss in the world but according to Dr Jürgen Kampmeier, current therapies, such as antibiotics, are often not successful in the treatment of this disease.

To combat this problem Dr Kampmeier, professor at the Department of Ophthalmology, University of Ulm, Germany, performed a comparative study of steam cautery and subablative Er:YAG laser therapy in microbial keratitis with the Institute for Lasertechnologies in Medicine and Metrology at the University of Ulm, Germany. The aim of the study was to find an effective and reliable method for the treatment of keratitis that is resistant to microbial therapy (originally presented at the WOC 2010 Congress, Berlin, Germany).

Background and methods

Steam cautery was developed by Karl Wessely early in the 20th century and he noted that the procedure leads to thermal necrosis associated with germ reduction. Dr Kampmeier and colleagues wanted to determine whether a procedure using an Er:YAG laser would provide an alternative viable option. "The advantages of the Er:YAG laser in comparison to steam cautery are a small well-defined zone of necrosis, a reproducible subablative heating and a contactfree application, that allows sterile treatment," he said.

In the comparative study, Dr Kampmeier's team, including Detlef Russ, physicist and the head of application research at the Institute of Lasertechnologies, examined the function and thermic effects of each procedure on fresh enucleated porcine eyes to reproduce conditions similar to that of corneal ulcers in humans. Thermal treatment was applied to the eyes and the measurement of the temperature was performed using an infrared, ultrafast thermal imaging system that is based on radiometry (CMT 256 M HS, Thermosensorik). The temperature required in the study was 60 °C or higher so that it is high enough to kill germs associated with keratitis.

To perform steam cautery, the team heated up the metal thorn to 90 °C using boiling water vapour. Eyes were treated at different contact times of 1, 2 and 3 s and the temperature of the contact surface was measured in dependence of this contact period. For the laser procedure a Burane XL Er:YAG laser of wavelength 2.94 µm was used (WaveLight GmbH, Erlangen, Germany). Treatment with the laser was performed using a single burst and the temperature of the corneal stroma was also measured at several pulse energies. Microscopic photography and histopathological examination were used to analyse the level of thermal injury caused to the eyes by each procedure.

In addition to this simulation was performed using a numeric method that demonstrated the heat distribution and level of tissue damage for each procedure.


On a scale of 1 to 10, with 1 being the lowest and 10 being the highest, how would you rate this article?
Your original vote has been tallied and is included in the ratings results.
View our top pages
Average rating for this page is: 6
WHAT DO YOU THINK?

AddThis Social Bookmark Button

Rate this article
Your comments
Discuss on our forum
Follow us on Twitter

 

Survey
Which clear corneal incision technique do you use the most?
Three-plane incision
Single-plane angled manual incision
Three-plane incision
53%
Single-plane angled manual incision
47%
Source: Ophthalmology Times Europe,
Click here