Flap adhesion under the spotlight
Comparing femtosecond with microkeratome


Ophthalmology Times Europe
Volume 5, Issue 1

Key iconKey Points

  • Professor Michael C. Knorz, MD and colleagues conducted a study in animal models and found that flaps were more than twice as stable when created with a femtosecod laser; he also discovered that an inverted side-cut provides greater stability than a standard side-cut. Higher energy levels were less desirable, as they are associated with inflammation and a greater degree of scarring.

Although there has been much discussion over whether mechanical microkeratomes or femtosecond lasers are better for performing refractive surgery in terms of both visual outcomes and safety, there remains one key metric that is essential for measuring the success of the procedure: flap stability.


Poor postoperative flap adhesion can mean that the eye responds poorly to trauma, leading to complications (including flap dislocation and possibly corneal ectasia) and surgical failure; greater flap stability is associated with more favourable outcomes. Whichever tool creates a more stable flap is likely also to produce more satisfactory surgical outcomes.

Flaps created with femtosecond lasers have previously been shown to provide greater stability when compared with microkeratome flap creation.1 Michael C. Knorz, MD had noticed in his clinic during LASIK retreatments that femtosecond flaps appeared more difficult to lift than microkeratome flaps, and so he conducted a study to evaluate the effects of the cutting tool (as well as cut angle and, with the femtosecond, laser energy) on flap stability. Professor Knorz used AMO's IntraLase iFS femtosecond laser and compared the results with those obtained using Ziemer's Amadeus II microkeratome.

Preparing the flaps

"We conducted these tests on rabbit eyes. The 14 rabbits were divided into four groups, and I conducted all the surgeries personally," said Professor Knorz. "We know that surface quality, flap thickness and shape, and corneal biomechanics and aberrations can influence surgical outcomes, but we concentrated on flap stability, and which instrument created the more stable flaps."

The microkeratome group included five eyes, and Professor Knorz created the nasal hinge using a 9 mm suction ring and a 140 µm head. The remaining three groups were operated on with different configurations of the IntraLase iFS femtosecond laser.

"In each of the femtosecond groups, we created 120 µm flaps with a diameter of 9 mm by using a repetition rate of 150 kHz. Group Two used a normal energy (0.8 µJ) side-cut on four eyes; Group Three used a high energy (1.6 µJ) side-cut on four eyes, and the final group of four eyes was operated on using an inverted side-cut, with an angle of 140° as opposed to 70°," explained Professor Knorz.

All the eyes with normal flaps were clear by day six, and this state maintained until the end of the study period (day 75). Of the corneas with amputated flaps that developed haze, most had cleared by day 75.

Postop flap excision: testing adhesion strength

For the first 15 days postoperatively, all eyes were treated three times daily with gentamicin sulphate 0.3% ophthalmic solution and dexamethasone
1 mg/mL ophthalmic solution. At day 75, the rabbits were euthanized and their corneal epithelia were excised with a hockey knife.

"After the epithelium was removed with a hockey knife, we used cynoacrylate ester to glue the flap surface to a plano-concave acrylic lens, which had a 10 mm radius curve and was attached to an aluminium holder. Both the acrylic lens and the holder were custom-made by AMO, and we were very careful to ensure that we glued just the flap and left the peripheral cornea untouched," clarified Professor Knorz. "Once the glue had been applied, we applied moderate pressure manually for six minutes while the glue dried."

A digital force gauge, model 475040 (Extech Instruments) was the tension meter used to measure adhesion strength. This was achieved by attaching the tension meter to the aluminium holder with a rope and pulling — at an angle of approximately 60° towards the hinge — until the flap dehisced.


On a scale of 1 to 10, with 1 being the lowest and 10 being the highest, how would you rate this article?
Your original vote has been tallied and is included in the ratings results.
View our top pages
Average rating for this page is: 1
WHAT DO YOU THINK?

AddThis Social Bookmark Button

Rate this article
Your comments
Discuss on our forum
Follow us on Twitter

 

Survey
What's your view of online learning/education for ophthalmology?
It would help me do my job better
Europe is well served
Europe is poorly served
Needs to be nationally orientated
Needs to be European orientated
Would never use
It would help me do my job better
100%
Europe is well served
0%
Europe is poorly served
0%
Needs to be nationally orientated
0%
Needs to be European orientated
0%
Would never use
0%
View Results
Thank you for voting
Source: Ophthalmology Times Europe,
Click here